Skip to main content

Power supply 100-240VAC/24VDC 2A

Item Number: 2990000063

Switched-mode power supply, 1-phase, 24 VDC output voltage, 2A current

  • Switched-mode power supply
  • Natural convection cooling when horizontally mounted
  • Enclosed for use in switchgear cabinets
  • Limited Power Source (LPS) per NEC Class 2
  • Bounce-free switching signal (DC O K)
  • Suitable for both parallel and series operation
  • Electrically isolated output voltage (SELV) per EN 60950-1/UL 60950-1; PELV per EN 60204
  • GL approval, also suitable for EMC 1 in conjunction with 787-980 Filter Module
INPUT
Phases 1
Nominal input voltage 100 to 240 VAC
Input voltage range 85 to 264 VAC; 120 to 372 VDC
Input voltage derating -2.5 %/V (< 95 VAC)
Input current ≤ 0.48 A (240 VAC); ≤ 0.82 A (100 VAC)
Discharge current ≤ 0.25 mA
Inrush current ≤ 30 A
Power factor correction (PFC) Passive
Mains failure hold-up time ≥ 120 ms (230 VAC); ≥ 20 ms (100 VAC)
OUTPUT
Nominal output voltage 24 VDC (SELV)
Output voltage range 23 to 28.5 VDC (adjustable)
Factory preset 24 VDC
Nominal output current 2 A (24 VDC); 2.2 A (< 40 °C)
Nominal output power 48 W
Residual ripple ≤ 20 mV (peak-to-peak)
Overload behavior Constant current
SIGNALING AND COMMUNICATION
Signaling 1 x LED DC OK (green); 1 x active signal output DC OK (24 VDC, 20 mA)
Operation status indicator LED green
Efficiency
Power loss ≤ 1W (230 VAC; no load); ≤ 6W (230 VAC; nominal load)
Max. power loss ≤ 7W (100 VAC / 24 VDC; 2 A)
Efficiency ≥89%
FUSE PROTECTION
Internal fuse T 4 A / 250 VAC
External fuse (required) External DC fuse required for DC input voltage
External fuse (recommended) Circuit breakers 6 A, 10 A, 16 A, characteristic: B or C an external DC fuse required for DC input voltage
GENERAL
Dimensions (WxHxL) 45mmx90mmx107.5mm
Weight 210 g
Type of mounting DIN-35 rail
Protection class II
Degree of protection IP20
Environmental
Operating Temperature -25 to 70 °C
Storage Temperature -25 to 85 °C
Relative humidity 5-96 % (no condensation permissible)
Derating -3 %/K (> 50 °C)
STANDARDS
Conformity marking CE
Standards/specifications EN 60950-1; EN 61204-3; EN 60335-1; UL 60950-1; UL 508; GL
Flowire Ethernet Converter - non-PoE.picture

FCDC2

Flowire Ethernet Converter - non-PoE This product has been replaced by 1008080310 FCDC3 Flowire Ethernet Converter

FCDC3

Flowire Ethernet Converter - DC Voltage

Date Name Category Size Document
7.07.2023 MD-SDoC-2990000063-IHM-8003-41819-115289 Declaration 72.15 KB Login to download
6.10.2021 GL-Zertifikat-14788-15HH-20150901.pdf Certificate 1015.02 KB Download
6.10.2021 787-1606_2990000063_Manual.pdf Manual 243.92 KB Download
6.10.2021 787-1606_2990000063_Datasheet.pdf Datasheet 536.27 KB Download
6.10.2021 Type Approval Certificate_TAA00002YC-2.pdf Certificate 72.91 KB Download