Skip to main content

Powerbox PSU, 24V DC, 120W

Item Number: 2990102120

Flowire Ex

  • GL approved for bridge use (pending)
  • EN60945 compliant
  • Universal input (90 – 265Vac)
  • Efficiency above 90%
  • Active Power Factor Correction
  • Adjustable output
  • Overload and overvoltage protection
  • Thermal overload protection
  • Conformal coating
  • DC OK signal and potential free contact
  • Cooling by free air convection
  • DIN-Rail mounting on back or side
  • RoHS compliant
  • Internal redundancy diode
  • Single or parallel mode user selectable
Input
Input range 90 – 265 Vac , 125 – 375 Vdc.
Frequency 47 – 63 Hz, 440 Hz with reduced PFC.
Inrush Current 30 A; cold start @ 230Vac / 25°C.
Input current <0.65A @ 230Vac.
Input fuse 3.15AT, internal, not user serviceable.
Efficiency >90%.
Leakage current <3.5 mA.
Output
Output voltage 24 V, adjustable 23 - 29V
Output power 125W. Peak power 187.5W (10s).
Minimum load 0A.
Load Regulation ±0.5 %.
Temperature coefficient ±0.02 %/°C.
Overvoltage protection 32V
Overload protection User selectable (see table 1).
Peak short circuit current 10 A (< 100 ms).
Overtemp. protection ±90°C internal temp.
Turn-on delay <2 s @ 90 Vac
DC OK signalling Green LED on front.
Potential free contact;
active closed; I < 1 A.
open voltage < 30V.
Environmental
Thermal performance
Operating temperature –25 - +70°C without derating.
Storage temperature –40 - +85°C.
Humidity 5 - 95%; non-condensing @ +55°C
Conformal coating.
Vibration Germanischer Lloyd table 3.16.
High vibration strain.
±1.6 mm displacement; 2 – 25 Hz
4g; 25 – 100 Hz (1 octave/min)
General
Isolation voltage Input/Output 3000 Vac. Input/Chassis 2000 Vac.
Dimensions 132 x 37 x 128 mm (H x W x D) .
Excluding DIN-Rail mounting device.
Add 10 mm for standard mounting device and EN50022 DIN-Rail.
Weight < 0.8 kg.
Standards
Safety standard According to EN60950.
EMC Emissions EN60945 conducted & radiated.
Harmonics EN61000-3-2 compliant.
ESD EN61000-4-2 Air ± 8 kV, Contact ± 6 kV.
Electromagnetic fields EN61000-4-3 10V/m 8MHz-2GHz.
EFT/Burst EN61000-4-4 2kV.
Surge EN61000-4-5 Line - Line 0.5kV, Line - GND 1kV.
Conducted immunity EN61000-4-6 3VRMS, 150kHz-80MHz.
Conducted LF IEC60533 3VRMS, 50Hz-12kHz.
HV immunity IEC60947-2 2kV, 60s.
GL Germanischer Lloyd
Environmental category: D, EMC1.
Guidelines for the Performance of Type.
Approvals Chapter 2, Edition 2003.
CE Low Voltage Directive 2006/95/EC.
EMC Directive 2004/108/EC.

No documents available for this product.