Skip to main content

ENA2400-DC

Item Number: 1023102400

Exigo Network Amplifier 2 x 400W

alphacom_40x40 ICX-AlphaCom
EXIGO_40x40 Exigo
  • 2x 400 watt continuous effect
  • Power efficient class D technology
  • 48 VDC power
  • Redundant Ethernet connections
  • Digital audio processing, equalizer and audio delay
  • Loudspeaker line monitoring
  • Input for backup amplifier
  • Tick tone generator
  • 6 configurable control outputs
  • 6 configurable control inputs

The Exigo Network Amplifier is designed for use in marine, offshore and other demanding environments. The amplifier utilizes state-of-the-art class D amplifier technology to ensure high power efficiency and superb audio quality.

The Exigo Network Amplifier is part of the Exigo PA/GA system, which is based on standard Ethernet network and digital processing. Each amplifier has two network connections, allowing for redundant cabling between the amplifier and the network. Using standard network equipment also allows for a much wider selection of standard network equipment.

The digital audio processing and maintenance of the amplifier is done with the embedded CPU and DSP. These components allow the amplifier to do advanced audio processing such as automatic gain control and equalizing while also maintaining a robust connection to the system controllers.

The complete amplifier is self-monitoring and this includes advanced monitoring of the speaker lines and internal system. The audio output channels can be monitored for line faults such as shorts, ground faults and large load changes. In addition, up to 10 intelligent Line End Transponders (ELTSI) can be placed on the speaker lines for additional accuracy in the line monitoring. The amplifier also monitors control inputs, power supplies, temperature, network connections and every other components required for operation of essential services. Faults will be reported to the system controller, but will also be indicated locally on the amplifier.

The amplifier operates from a 48 VDC supply and is designed to survive minor interruptions on the power supply.

The amplifier’s configurable control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or can be controlled by the system (e.g. audio input for background music).

MECHANICAL
Dimensions (HxWxD) 87 x 482 x 390 mm
Weight 13.5 kg
Shipping Weight 15 kg
Mounting 19” Rack, 2HU
Color Black
USER INTERFACE
Display 3.5” QVGA Color TFT LCD
Button Rotary selector button with push-to-select
Indicators Power, Fault, Disabled
ENVIRONMENTAL
Operating temperature -15 °C to +55 °C
Operating humidity 15% to 95% (non-condensing)
Storage temperature -40°C to +70°C
Storage humidity 10% to 95% (non-condensing)
Air pressure 700 hPa to 1300 hPa
IP rating IP-32
ELECTRICAL
Connector Pluggable and lockable terminal
Nominal voltage 48 Vdc, Vmin 40 Vdc, Vmax 63 Vdc
Inrush current Max 26 A
Power consumption Pnom: ≤ 35 W (idle) Pmax: ≤ 1250 W
* Power consumption calculated with continious 6A 800 watt load on outputs, 10 LET units, all control I/O activated
AUDIO OUTPUTS
Output power (100V/70V) 2 x 400 Watt GA power, continuous @ 55 °C
25V (8 ohm) output 2 x 50 watt alarm, continuous @ 50 °C
Output line 100 volt, 70 volt and 8 Ohm
Frequency response 200 Hz to 20 kHz ±3 dB
Audio codec G711, G722, PCM L16/48kHz
SNR 86 dB in test-modus, A-weighted noise
THD < 0.5% @ 1 kHz
Rated load resistance 100V: 25 Ω, 70V: 12,5 Ω, 25V: 25 Ω
Rated load capacitance 470 nF
NETWORK
Ethernet 2 x 10BASE-T, 100BASE-TX, Auto negotiation, Auto MDIX
Protocols Protocols IPv4 (with DiffServ), TCP, UDP, HTTPS, TFTP, RTP, DHCP, SNMP, STENTOFON CCoIP® , NTP
LAN Protocols VLAN(IEEE 802.1pq), Network Access Control (IEEE 802.1x), STP (IEEE 802.1d)
Management and operation HTTP/HTTPS (Web configuration) DHCP and static IP Remote automatic software upgrade Centralized monitoring
Line input
Frequency response 80 Hz – 20 kHz
Audio codec G711, G722, PCM L16/48kHz
Nominal input level 100 mVRMS – 1 VRMS
SNR 80 dB
CMRR 45 dB
Input impedance 600 Ω / 10 k Ω (selectable)
Microphone input
Frequency response 80 Hz – 20 kHz
Audio codec G711, G722, PCM L16/48kHz
Nominal input level 1 mVRMS – 100 mVRMS
SNR 80 dB
CMRR 45 dB
Input impedance 600 Ω / 10 k Ω (selectable)
Phantom supply (optional) 12 VDC ±10% @ 15 mA (IEC 61938, P12)
Control inputs and control outputs
Control Inputs 6
Type Closing contact, monitored
Control Outputs 6
Relay outputs: (COM, NO,NC) Max recommended levels: 3A, 100Vdc, 125Vac, switching 60W/125VA
24 V outputs 24 VDC ±10%, 200 mA, monitored
Fault relay 1
Relay outputs: (COM, NO,NC) Max recommended levels: 3A, 100Vdc, 125Vac, switching 60W/125VA
Certifications
Immunity EN 60945, EN 50130-4, EN 61000-6-1, EN 61000-6-2, EN 55103-2
Emissions EN 60945, EN 61000-6-3, EN 61000-6-4
Safety EN 60065, EN 62368-1, IEC 60529

ENA2400-DC

Exigo Line End Transponder ELTSI-1

ELTSI-1

Exigo Industrial Line End Transponder

Date Name Category Size Document
16.05.2023 MD-SDoC-1023102400-IHM-8003-41773-50172 Declaration 72.14 KB Login to download
2.01.2023 Exigo - Bureau Veritas Type Approval Certificate 51006-A0 BV Certificate 278.33 KB Download
1.11.2022 RoHS Declaration 2021 Declaration 3.24 MB Download
12.02.2021 A100K11694 Replacing Amplifier Module on ENA2400 Manual 925.85 KB Download
12.02.2021 A100K11605 Replacing ENA2200/ENA2400 Amplifier Manual 253.9 KB Download